0755-23251735 Chinese/English

Product List

S-2403 Chromogenic Substrate: A Substrate Choice for Plasminogen, Plasmin, and Inhibitor Activity Assays

2026/11/11 16:20:34 Browse volume(51)
Plasmin Chromogenic Substrate

S-2403


In coagulation and fibrinolysis testing, Plasminogen is an important component of the fibrinolytic system. However, unlike Plasmin, which already has catalytic activity, Plasminogen itself is in a zymogen state and cannot directly reflect its catalytic activity through substrate hydrolysis reactions.

So, how can the functional state of Plasminogen be converted into a measurable detection signal?

A common approach is: first convert Plasminogen into Plasmin through an activation system, and then use a chromogenic substrate to detect the activity of the generated Plasmin. Through this process, zymogen activation and enzymatic chromogenic reactions can be linked.

In this detection system, the chromogenic substrate plays an important role in converting enzyme activity into an optical signal. S-2403 (Pyr-Phe-Lys-pNA) is a peptide chromogenic substrate that can be used for Plasmin activity detection.

I. From Detection Needs to Product Solution: S-2403 Chromogenic Substrate

Chromogenic Substrate S-2403 364605-58-3 structural formula

Chinese name: Chromogenic Substrate S-2403

English name: Pyr-Phe-Lys-pNA · HCI

Chemical name: L-Pyroglutamyl-L-phenylalanyl-L-lysine-p-nitroaniline hydrochloride

Abbreviation: S-2403

CAS No.: 364605-58-3

Molecular Formula: C26H33CIN6O6

Molecular Weight: 561.04

Specification: 1 g/5 g/25 g (custom packaging supported)

Appearance: off-white crystalline powder

Catalog No.: G04010010

Color: Yellow

Chromogenic Substrate S-2403 is composed of L-pyroglutamyl, L-phenylalanine, L-lysine, and p-nitroaniline (pNA), in which pNA serves as the chromogenic group and undertakes the chromogenic signal reporting function.


II. Working Principle: How to Convert Plasmin Activity into a Chromogenic Signal?

The detection basis of Chromogenic Substrate S-2403 is the enzymatic hydrolysis reaction of Plasmin on peptide substrates. The whole process can be divided into three steps: substrate hydrolysis, chromogenic signal release, and absorbance monitoring.

1. Plasmin hydrolyzes the peptide substrate

Chromogenic Substrate S-2403 contains a peptide structure related to Plasmin substrate recognition. When Plasmin catalyzes substrate hydrolysis, it can cleave the bond between the terminal lysine and p-nitroaniline, releasing the terminal p-nitroaniline group.

2. Release of p-nitroaniline produces a yellow chromogenic signal

Free p-nitroaniline has chromogenic properties, forming a yellow signal after release. As the enzymatic reaction continues, p-nitroaniline is gradually generated, and the absorbance of the reaction system also changes accordingly.

3. Analyze enzyme activity through absorbance changes

Under suitable reaction conditions, absorbance changes can be monitored at a wavelength of approximately 405 nm. Depending on the detection method, the rate of absorbance change per unit time (ΔA/min) can be analyzed using a kinetic method, or endpoint analysis can be performed using the absorbance after a specified reaction time.

It should be noted that S-2403 is not an absolutely specific Plasmin substrate. Some trypsin-like serine proteases with corresponding substrate recognition capabilities may also hydrolyze this substrate. Therefore, in complex sample detection, it is necessary to control interference from non-target enzymes by combining the enzyme selectivity of the detection system, inhibitors, and sample pretreatment conditions.

For direct Plasmin activity detection, S-2403 can directly participate in the substrate hydrolysis reaction; for Plasminogen activity detection, it is necessary to first generate Plasmin through an activation system and then use S-2403 for subsequent determination.

The key difference between the two detection approaches is that S-2403 directly detects Plasmin activity, while Plasminogen activity needs to be indirectly evaluated through the Plasmin activity generated after activation.

This process links the activation process of Plasminogen with the catalytic reaction of Plasmin, enabling the functional activity of the zymogen to be evaluated through a measurable chromogenic signal.


III. Application Scenarios: Applications of S-2403 in Fibrinolysis Testing

The applications of S-2403 revolve around the catalytic activity of Plasmin. Depending on the detection target and reaction system, it can mainly be used for Plasminogen activity detection, Plasmin activity detection, and Plasmin inhibitor activity detection.

1. Plasminogen Activity Assay

Plasminogen is an important zymogen in the fibrinolytic system, and its functional activity is usually evaluated through the Plasmin generated after activation. In the detection system, Plasminogen can be activated using streptokinase or urokinase, and then the generated Plasmin activity can be measured using S-2403, thereby indirectly reflecting the functional activity of Plasminogen in the sample.

This detection method can convert the functional state of Plasminogen into a measurable enzyme activity signal, and is suitable for the development of Plasminogen activity detection reagents and related analytical methods.

2. Plasmin Activity Assay

Plasmin is a key protease in the fibrinolytic system and participates in the fibrin degradation process. For the activity analysis of Plasmin itself, S-2403 can be directly used as a chromogenic substrate.

In the detection system, Plasmin hydrolyzes S-2403 and releases p-nitroaniline. By measuring the absorbance change of the chromogenic reaction, the catalytic activity of Plasmin can be analyzed.

This method is suitable for Plasmin activity determination, enzymatic property research, and activity analysis and quality control of Plasmin-related enzyme preparations. For research that requires continuous observation of enzymatic reaction changes, reaction rate information can also be obtained through kinetic absorbance monitoring.

3. α2-Antiplasmin Activity Assay

The fibrinolytic system is not only regulated by the activation process but also has corresponding inhibitory mechanisms. Among them, α2-Antiplasmin is an important physiological Plasmin inhibitor that can interact with Plasmin and inhibit its proteolytic activity.

In the α2-Antiplasmin activity assay, a certain amount of Plasmin can first be reacted with the sample to be tested, and then S-2403 can be added to determine the residual Plasmin activity. The stronger the inhibitory effect of α2-Antiplasmin in the sample, the lower the residual Plasmin activity participating in subsequent substrate hydrolysis is usually.

By measuring the residual Plasmin activity after the reaction, the functional activity of α2-Antiplasmin in the sample can be indirectly evaluated. This residual enzyme activity detection method also provides a substrate option for the development of related inhibitor activity detection reagents.


IV. From Detection Method to Raw Material Selection: Core Advantages of S-2403

✅ Good water solubility, convenient for experimental and production-level preparation

The hydrochloride salt of S-2403 has a solubility in water exceeding 40 mM, making it convenient to prepare substrate working solutions of different concentrations, adapting to different needs from R&D screening to production-level reaction systems and reducing preparation adjustments caused by solubility limitations.

✅ Mature detection system references available, convenient for R&D application exploration

S-2403 is a peptide pNA substrate used in existing Plasmin chromogenic substrate detection methods, and the related technical route has been applied to Plasmin activity, Plasminogen activity, and α2-Antiplasmin activity detection. Existing method literature and commercial detection systems for product applications can provide references for substrate selection and detection scheme design.

✅ Higher catalytic efficiency, improving substrate reaction performance

Compared with the commonly used Plasmin chromogenic substrate S-2251, S-2403 has higher catalytic efficiency (kcal/Km), which is beneficial for improving the enzymatic reaction efficiency between the substrate and Plasmin and provides a good substrate option for Plasmin activity detection.

✅ Suitable for automated detection, meeting multi-sample analysis needs

Faster chromogenic reactions help shorten the analysis cycle of a single test, adapting to the needs of automated coagulation analysis platforms for short incubation and high throughput, and providing substrate support for continuous multi-sample analysis and standardized testing.

✅ One-stop coagulation and fibrinolysis configuration, stable domestic supply

S-2403 is domestically developed, with multiple specifications available. Thrombin, FXa, and Plasmin substrates can be fully configured at GeneSeqTools Bioscience & Technology, reducing single-point dependence on imported raw materials, shortening procurement links, and supporting a smooth transition from R&D to production.



Extended Services

Quantifiable plasmin signal, connectable domestic supply substrate.

For more "coagulation testing chromogenic substrates" or customized packaging services, please call +86 13302967066!

GeneSeqTools Bioscience & Technology focuses on providing reliable domestic substitution solutions for gene sequencing, molecular diagnostics, and microbial testing.

For related products such as blood cell dyes and buffer salts, you can view the complete product line and technical specifications at[MedSun Biotechnology Website].


In Vitro Molecular Diagnostics | Gene Sequencing | Microbial Testing
END


gst_logo.jpg
Shenzhen GeneSeqTools Bioscience & Technology Co. Ltd.

Founded in 2015, it is a high-tech enterprise focusing on microbial testing、 gene sequencing and in vitro molecular diagnostics in the R&D, production, and sales of biochemical reagent raw materials. Committed to providing high-quality biochemical reagent raw materials and professional custom synthesis services, the product portfolio covers more than a dozen categories and nearly a thousand innovative products. Upholding the core philosophy of “customer first, integrity and professionalism”, we serve with dedication to meet customers’ diverse needs in research and testing.

Shenzhen GeneSeqTools Bioscience & Technology Co. Ltd. WeChat official account QR code
Follow Us
Get the latest product updates

Official WeChat account: Shenzhen GeneSeqTools Bioscience & Technology Co. Ltd.

GeneSeqTools official website: http://www.geneseqtools.com

Hotline: +86 0755-23251735

QQ: 2370561481

Email: sales@geneseqtools.com

All products are used for scientific research or industrial applications only.

scan it,Follow us